Posted Date: 13 Apr 2020

In our last and rather long blog post, we discussed how Supplement No. 1 to ASCE 7-16 made an important correction to Table 11.4-2, Long-Period Site Coefficient, Fv. We also discussed how that correction introduced a new problem. In this blog post, we would like to say a few more things on the latter item because, as a result of that, we are continually receiving emails from designers who, under certain circumstances, are now receiving some very confusing output from various online tools that provide mapped and design ground motion parameters as well as the Seismic Design Category (SDC) of a structure.

Please do read the earlier blog for a detailed description on how we arrived at this situation.

The problem is related to the highlighted portions of Table 11.4-2 shown below:

ASCE 7-16 Supplement No. 1 Table 11.4-2 Long-Period Site Coefficient, Fv

Site Class Mapped Risk-Targeted Maximum Considered Earthquake (MCER) Spectral
Response Acceleration Parameter at 1-s Period
S1 = 0.1 S1 = 0.2 S1 = 0.3 S1 = 0.4 S1 = 0.5 S1 ≥ 0.6
A 0.8 0.8 0.8 0.8 0.8 0.8
B 0.8 0.8 0.8 0.8 0.8 0.8
C 1.5 1.5 1.5 1.5 1.5 1.4
D 2.4 2.2a 2.0a 1.9a 1.8a 1.7a
E 4.2 3.3 2.8 2.4 2.2 2.0
F See Section
11.4.8
See Section
11.4.8
See Section
11.4.8
See Section
11.4.8
See Section
11.4.8
See Section
11.4.8
Note: Use linear interpolation for intermediate values of S1.
aSee requirements for site-specific ground motions in Section 11.4.8. These values of Fv shall be used only for
calculation of TS.

Per Footnote a, for Site Classes D and E and for S1 ≥ 0.2, the Fv values given in the table are only to be used for the purpose of determining TS, which is needed to see if the structure qualifies for one of the exemptions included in Section 11.4.8 from the requirement of site-specific ground motion analysis. However, no guidance is provided on what to do if a structure does qualify for an exemption. Some value of Fv is still required for determining SD1 not only for calculating the design base shear but also for determining the SDC of the structure. Since ASCE 7-16 literally states that the values of Fv in Table 11.4-2 are for calculation of TS only, the online ground motion tools are simply not providing any value of SD1 and SDC, leaving the users confused and frustrated.

The good news is, a Supplement No. 3 to ASCE 7-16 is in the works to mitigate this issue, and also to incorporate some more improvements in the relevant provisions. The bad news is, it will still take a few months for that supplement to go through the balloting and approval processes and be released. While we wait for that Supplement to be published, here is a quick fix for the issue, which will likely be the resolution the supplement will offer: simply revise Footnote a as shown below:

“These values of Fv shall only be used for calculation of TS and for the calculation of SD1 when following the exceptions of Section 11.4.8.

Unfortunately, the online tools will very likely wait for the Supplement to be published before making any changes to their algorithm. But designers can still utilize the above suggestion to manually determine SD1 and SDC for their structures.